Hamilton Ventilator Flow Sensor

Studies have shown that tidal volumes for ventilated patients should be determined with a flow sensor placed at the endotracheal tube.
Hamilton ventilator flow sensor. The proximal flow sensor is a central compone. Revolutionizing critical care ventilation in 1983 hamilton medical was founded with a vision. The hamilton g5 receives inputs from the proximal flow sensor and other sensors within the ventilator. In combination with the co2 mainstream sensor the flow sensor can be used for volumetric capnography to obtain a wide range of additional parameters for assessing the.
Page 14 2 6 connecting a co2 mainstream sensor attaching the co2 sensor to the airway adapter co2 sensor airway adapter connect to co2 port on ventilator connecting the co2 sensor adapter to the patient circuit you can connect the co2 sensor before or after the flow sensor according to your institution s protocol. Gas supply and delivery general information the hamilton g5 has several means to ensure that safe patient pressures are maintained. To develop intelligent ventilation solutions that make life easier for patients in critical care and for the people who care for them. Watch the video and find out.
The hamilton 28167 flow sensors with 15m x 15f 22m connectors. Using hamilton medical originals ensures the best performance and safety of your hamilton medical ventilators. 1 physically the flow sensor is a thin membrane within a plastic housing. A vision drives hamilton medical.
To provide better ventilation care to critically ill patients and unburden the people who care for them more intelligent ventilation since 1983 hamilton medical in the usa. Hamilton medical ventilators measure flow and pressure close to the patient s airway. Includes a single use 22m x 22m calibration adapter it compatible with hamilton g5 galileo hamilton c2 raphael amadeus and veolar ventilators. 1 physically the flow sensor is a thin membrane within a plastic housing.
The flow sensor measures the actual flow pressure and volume proximal to the patient thereby eliminating any disturbances between the ventilator and the flow sensor itself. Studies have shown that tidal volumes for ventilated patients should be determined with a flow sensor placed at the endotracheal tube. User friendly as flow sensor tube connectors and expiratory valve set are all preassembled heated for humidification with the hamilton h900 or nonheated breathing circuit sets reduced risk of ventilator associated pneumonia vap due to single patient use.