Seasonal preventive maintenance on your heating and cooling system may guard against many unexpected failures and could maximize the lifecycle of your heating or cooling unit.
Heat pump cooling temperature output. Heat pumps main benefit. Up to 19 seer average running decibels. When the outside air temperature is very low an auxilery electric heater must be used to supplement the heat pump s output. At what temperature is a heat pump not effective.
Correction factors are often given for airflow from 350 cfm per ton to 450 cfm per ton also. A heat pump is most effective when supplemented by a secondary heat source at 25 30 degrees fahrenheit and below. Hvac system temperature faqs. At much higher humidifies the split can be as low as say 14 f.
The opposite for a cooling process a lower cold temperature will increase the efficiency. An air to air heat pump operates between temperature 5 o c on the cold side and temperature 40 o c on the hot side. Hopefully this article has helped answer that question and any others about heat pump temperature ranges and what you can do to improve heat pump performance when it gets below 25 30 degrees. So you were wondering at what temperature is a heat pump not effective.
At a humidity considerably below 50 the temp split will be considerably greater than 20 f. Example maximum heat pump efficiency. Heat pump effective temperature ranges a heat pump is most effective in temperatures of 30 degrees fahrenheit and above. The maximum theoretical efficiency can be calculated by using 1b as.
35 5 x 35 5 x 40 inches efficiency ratings. At around 50 indoor rh the split should be around 19 to 20 f. High and low pressure switches expanded comfortalert diagnostics built in comfortbridge technology two stage copeland ultratech scroll compressor factory. Air conditioner or heat pump operating temperature diagnostic questions answers.
56 500 btu physical unit size. A heat pump is a device that transfers heat energy from a source of heat to what is called a thermal reservoir heat pumps move thermal energy in the opposite direction of spontaneous heat transfer by absorbing heat from a cold space and releasing it to a warmer one a heat pump uses external power to accomplish the work of transferring energy from the heat source to the heat sink. 1 so if you have determined that you have a heat pump see 1 be sure to schedule pre season maintenance. Your job is to plot current temperature and airflow conditions to discover the rated btu output of the heat pump.
You need to know the indoor relative humidity to determine if the temp split is close to what it should be. How to get the necessary field test numbers. The heat pump is very efficient when the outside temperature is around 45 degrees fahrenheit to 50 degrees fahrenheit but it becomes less efficient as the temperature drops. Let s look at the work it takes before you can plot btu output on a heat pump performance table.
75 specialized features per unit type.